Your light show worked yesterday, the power blinked, and now a controller is missing? Don't reset everything. A power interruption can affect a power supply, network switch, controller, player, or the order in which they restart. This Mattos Designs checklist helps you find the failed stage without losing a working configuration.

Start safely: look, don't touch live wiring

If you smell burning, see water inside an enclosure, find damaged wiring, or notice repeated breaker trips, switch off power and have the installation checked by a qualified person. Never open or work on energized mains-voltage equipment. Do not bypass fuses or protection to make a show run.

Step 1: Identify what is actually offline

Is one prop dark, one entire controller missing, or the whole show stopped? Check whether the show computer or Falcon Player (FPP) is running and whether other controllers still respond. If every controller stopped together, investigate shared power, network, or player equipment before individual pixels.

Step 2: Check power at the right level

Look for the controller's normal status indicators and confirm the enclosure's power source is available. If the controller appears completely dead, don't assume the pixels failed. A power supply, breaker, protective device, or connection may need inspection. Check the manufacturer’s documentation for indicator meanings and safe test procedures.

Step 3: Check the network path

Verify the router or network switch restarted, Ethernet connections are secure, and the controller appears on the expected network. If you use Wi-Fi anywhere in the control chain, confirm it reconnected. A controller may be powered but unreachable because a switch or network device has not recovered.

Step 4: Check the controller's IP address

Compare the controller's current IP address with the address saved in xLights, Light-O-Rama, or your player configuration. If your network uses DHCP, the controller may receive a different address after a restart. A DHCP reservation or carefully planned static address can help keep controller addresses predictable. Avoid creating duplicate IP addresses.

Step 5: Confirm the controller is ready for show data

Once you can reach the controller, review its status and output mode. Confirm it is not stuck in a local test mode and that its input/output configuration is still correct. Do not factory-reset a controller just because it is not responding: first save screenshots or a backup of its settings if available.

Step 6: Test one output, then the real show

With the correct voltage and safe setup confirmed, use the controller's built-in test feature if available. Then test live output from your sequencing software. Finally, run the actual playlist or scheduled show. A built-in test working does not prove the player is sending data.

Step 7: If FPP runs the show, check the player

Confirm FPP restarted, the correct playlist is selected, output configuration is active, and the schedule is enabled. If your show depends on a network switch or router, make sure it is ready before testing playback. See our xLights-to-FPP setup checklist.

What the symptoms usually tell you

What you see Where to check first
Entire display stopped Shared power, show player, network switch, and schedule
One controller has no status lights Its power source and protection, following safe procedures
Controller is powered but unreachable Network link, IP address, switch, and routing
Controller test works but sequence does not Input protocol, xLights/LOR output, player, and mapping
Only one strand or prop is dark That output's fuse, connection, configuration, and pixel path

Prevent the same problem next time

  • Document controller names, IP addresses, and which props each port runs.
  • Keep a backup of xLights/LOR configuration, FPP settings, and controller configuration.
  • Label network cables and power supplies.
  • Consider suitable surge protection and power management for your installation.
  • Run a controlled restart rehearsal before opening night: confirm the system recovers and the scheduled show starts correctly.

Mattos-specific help

Running an MD1500 Baldrick? Start with the Baldrick network and recovery checklist and Baldrick troubleshooting guide. If the controller is reachable but xLights output is not working, use Pixels Work in Test Mode but Not in xLights?. For power and wiring fundamentals, visit RGB pixel power and wiring.

Still stuck? Contact Support@MattosDesigns.com with your controller model, the status lights you see, whether its web interface opens, your player/software, and which parts of the display still work. A short video of the symptoms helps us identify the next useful test.

— Mattos Designs